Recommended Tests per Class |
| Class |
1 |
10 |
100 |
1,000 |
10,000 |
100,000 |
| Floor Count |
* |
* |
* |
* |
* |
* |
| Velocity |
* |
* |
* |
* |
** |
** |
| Static Pressure |
* |
* |
* |
* |
* |
* |
| Face Scan |
* |
* |
1 |
1 |
1 |
4 |
| Laminarty |
* |
* |
1 |
2 |
n/a |
n/a |
| Parallelism |
* |
* |
1 |
2 |
n/a |
n/a |
| Recovery |
* |
* |
* |
1 |
1 |
1 |
Temp
Humidity
Light
Sound |
3 |
3 |
3 |
3 |
3 |
3 |
*Required test
**Recommended test
1. New projects only
2. Raised floor designs only
3. Customer/manufacturer dependent
4. Design may not allow face scan
Floor Count: Air samples taken by a particle counter at a height of 32" to 40" above the floor (sample times and air volume typically are 1 minute and 1 CFM).
Velocity: The speed of the air coming out of a filter (FPM feet per minute) assures even airflow through a room and gives you air change ratios.
Static Pressure:
- Filter: The amount of force it takes for air to pass through a filter.
- Room: The pressure difference of one room to another. Ex. main cleanroom vs. a gowning room vs. a hallway.
Face Scan: Testing the filter by passing a particle sample probe across its face looking for small pin hole leaks.
Laminarty: Airflow patterns within a room.
Parallelism: Indicates how straight the airflow is over a given distance.
Recovery: How quickly the room or area will clean itself up and return to normal.
Temperature, Humidity, Light, and Sound: The rated performance of each item at specified locations (typically 4'-10' on center).
|